THUS – 250 Universal Hardness Tester

Main features

1.Brinell, Rockwell, Vickers three test methods, more hardness scales to choose.
2.Electronic electric loading, high precision sensor, with a unique closed loop control system.
3.Eyepiece structure with digital encoder, measure D1, D2 value, LCD directly display hardness value and D1, D2 value.
4.The test force is automatically corrected, each force is automatically compensated, and the precision of the force is increased by an order of magnitude.
5.It can be calibrated according to standard hardness blocks or length scales.
6.The test force can be corrected automatically by standard dynamometer.
7.Rockwell and Vickers hardness values can be converted.
8.Touch screen interface, easy to operate.
9.Automatic conversion of hardness according to GB /ASTM.
10.Set password protection setting parameters, more sample and test information.
11.The measurement data is saved in EXCEL format on USB disk, which is convenient for editing and processing.
12.Optional upgrade to add HVT, HBT two ruler.(depth method)

Technical parameters:

Model THUS-250
Hardness scale Brucellosis, Vickers, Rockwell, Superficial Rockwell
Force 5 ~ 250 KGF
Brinell scale HBW1/ : 5, 10, 30kgf

HBW2.5/ : 6.25, 15.625, 31.25, 62.5, 187.5 KGF

HBW5/ : 25, 62.5, 125, 250kgf

HBW10/ : 100, 250kgf

Rockwell scale A, B, C, D, E, F, G, H, K, L, M, P, R, S, V

15N, 30N, 45N, 15T, 30T, 45T, 15W, 30W, 45W

15X, 30X, 45X, 15Y, 30Y, 45Y

Vickers scale HV5, HV10, HV20, HV30, HV50, HV100, HV120kgf
Measurement system The indentation image is collected by optical objective lens and CCD camera and measured in LCD interface.

Resolution:

Length reading: 0.1 micron

Depth reading: 0.2 micron

Magnification of objective lens 2.5x, 5X (optional 10X, 20X)
Camera 1280 by 1080 pixels, 1/2 inch
Data output Computer display
Test Automatic loading, load retention, unload
Indenter Rockwell diamond: 120°

Rockwell ball head: 1/16 „,

Vickers diamond: 136°

Brinell ball indenter: 1mm, 2.5mm, 10mm

(Rockwell ball indenter option 1/8 „, 1/4 „, 1/2 „)

Lighting system LED light, ring light
Execution standard GB/T230, GB/T231, GB/T4340, JJG144-1999, GB/T18449, ISO 6508, ASTM E10, ASTM E92, ASTM E18, ASTM E384, ASTM E103
Total experimental effort to maintain the load time 1-99 seconds
Sample size Maximum height of sample: 220mm

Head – outer wall distance (throat) :200mm

Cylindrical specimen: the minimum diameter of cylindrical specimen on the outer surface is 4mm;

Maximum test height Lowe’s: 220, Brucellosis: 150mm
Distance from center of indenter to outer wall 200mm
Dimension 500*260*750mm
Weight About 70 kg
Power AC220V + 5%, 50 to 60 hz
en_GBEnglish